An ISO 9001 : 2015 Certified Company

Low Voltage Control Cables

Specification:

Designation Type H07Z-U, H07Z-R and H07Z-K BS EN 50525-3-41 (Formerly BS 7211:1998). Flame Retardant to IEC 60332-1 Vertical Flame Propagation Test. Our products tested at internationally reputable labs, BASEC & bsi.

Conductor:

High conductivity soft annealed copper according to BS EN 60228, Class 1, Class 2 stranded and Class 5 flexible conductor.

Insulation:

Polyvinyl chloride (PVC) & Cross-linked polyethylene (XLPE) with Maximum service temperature 90ºC.

Insulation:

  • Copper wire screen - cross section are upon request.
  • Copper tape screen
  • Tinned copper & annealed copper wire Braided
  • Lead sheath

Armoring (upon request):

Galvanized Steel Wire “SWA” or Galvanized Double Steel Tape “STA"

Outer Sheathing:

PVC ST2 and LS0H ST8

Special Requirement (upon request):

  • High fire performance, Flame propagation tests: IEC 60332-3.24 Category C - IEC 60332-3.23 Category B - IEC 60332-3.22 Category A
  • Fire resistant control cable with MICA - BS 6387 CAT CWZ
  • Chemical performance: Oil resistance
  • Sunlight & UV Resistant
  • Water resistance
  • Anti-termite resistant
  • Special color for insulation and outer sheath
  • Numbering identification for cores
  • Special outer sheath material: PVC(FRLS), PE
  • Different packing options are available
XLPE insulated LS0H sheathed cables 0.6/1.0 kV and 1.8/3.0 kV, IEC & BS Standards

Specification:

Electrical low voltage cables complying with IEC 60502-1 BS 6724. Our products tested at internationally reputable labs, BASEC & bsi. All cable are Flame Retardant to IEC 60332-3.24 Category C Flame Propagation Test, Oil resistance and Sunlight & UV Resistant.

Conductor

High conductivity soft annealed copper according to BS EN 60228, Class 1, Class 2 stranded and Class 5 flexible conductor and Stranded aluminum conductor Class2. Conductor can be offered with round, round compacted and sectored shape.

Insulation

Cross-linked polyethylene (XLPE) with Maximum service temperature 90ºC.

Armoring (upon request):

  • Aluminum Wire Armored “AWA” for single core cable.
  • Galvanized steel wire “SWA” for multi core cable.

Outer Sheathing

Low Smoke & Fume Zero Halogen (LS0H).

Special Requirements (upon request):

  • High fire performance, Flame propagation tests: IEC 60332-3.23 Category B - IEC 60332-3.22 Category A
  • Water resistance
  • Anti-termite resistant
  • Shield type
  • Special color for insulation and outer sheath
  • Different packing options are available